Flo-tech Hydraulic Diagnostic Testers — Portable Pump, Motor & Valve Test Instruments
Turn a suspected pump or valve fault into a measured reading — supplied by a company that runs its own hydraulic test systems for cylinders, manifolds and valves.
Is the pump weak, or is the valve leaking past its seat? On a working hydraulic circuit that question usually gets answered by guesswork and part-swapping — unless you can break into the line at one point and read flow, pressure and temperature together. That's exactly what Flo-tech's turbine-based portable testers are built to do, and it's why Concord Hydraulics carries the range alongside Hedland as part of our Badger Meter instrumentation offering.
We don't just distribute these testers — we use the same kind of measurement discipline on our own shop floor, where our in-house hydraulic test systems for cylinders, manifolds and valves and also are part of every pump and motor rebuild we carry out.
What Flo-tech Testing Is Typically Used For
Flo-tech testers are commonly specified for pump and motor volumetric-efficiency checks, valve and cylinder internal-leakage testing under working pressure, preventive-maintenance baselining to catch gradual wear before failure, acceptance testing on rebuilt components, and troubleshooting hydrostatic transmission or power-steering circuits.
Download Flo-tech Catalogue & User Manual
Full product range, flow ranges and specifications, plus the operating guide for PFM portable testers.
Flo-tech Hydraulic Testers FAQ
Understanding hydraulic testers
The hydraulic tester is a diagnostic instrument connected in line with a hydraulic circuit. These may be portable testers that could be carried by Mobile Hydraulic Repair Teams or fixed inline devices that can be assembled on Hydraulic Systems. Fluid turns a turbine rotor, and a magnetic pick-up creates a signal proportional to flow rate. A built-in temperature sensor reads fluid temperature, and a pressure sensor or gauge reads pressure. A loading valve lets you raise pressure in a controlled way, so you can see how a pump, valve or motor behaves under load. Flo-tech testers are designed for pumps, valves, cylinders, motors, hydrostatic transmissions and power steering systems.
It can show:
- Pump wear (flow falling as pressure rises)
- Suction problems (low flow at zero and at full pressure)
- Relief valves opening early or set incorrectly
- Internal leakage in directional control valves
- Hydraulic motor wear (speed loss, rising case drain flow)
- Cylinder piston seal leakage
- Power loss, calculated from flow and pressure
The result provides measurable evidence for a repair-or-replace decision, supporting service reports and customer approval.
A pressure gauge alone cannot find a worn pump, because a worn pump can still reach full pressure at reduced flow. Flow shows the volume of oil actually delivered, pressure shows the load, and temperature shows where lost energy is turning into heat. Measured together at one point, they locate the failing component faster than separate gauges and meters.
Use a portable tester when the machine cannot be moved, for example on a rig, vessel, wind turbine or production line. Use a test bench when you need repeatable, controlled testing of removed components, such as acceptance testing of a rebuilt pump, motor or valve. Many repair teams use both. Flo-tech instruments work in either role: the same Flo-Check USB analyzer can be used stationary or portable, and can be added to an existing test stand
Pump, motor, valve & cylinder testing
Following the Flo-tech procedure:
- Install the tester in a tee or inline configuration between the pump and the rest of the circuit, and plug the line to the control valve.
- Open the tester's loading valve fully, start the pump at rated speed and read maximum pump flow at zero pressure.
- Close the loading valve gradually to raise pressure from zero to rated pressure while recording flow.
- Compare flow at rated pressure with the pump manufacturer's specification.
A decrease in flow from zero pressure to maximum pressure shows the pump's condition. A pump that gives constant low flow at both zero and maximum pressure suggests suction problems.
Volumetric efficiency (%) = actual flow at pressure ÷ theoretical flow × 100, where theoretical flow is displacement multiplied by shaft speed. Read actual flow from the tester at rated pressure, and use the pump datasheet for displacement. A drop in efficiency as pressure rises indicates internal leakage. Take all readings at the same oil temperature, because viscosity changes leakage. The manuals suggest testing at a consistent operating temperature, with 150 °F (66 °C) typical for mobile machinery.
A healthy pump keeps its output flow close to the manufacturer's figure at rated pressure and shows case drain flow at or near the new-pump baseline. Measure output flow with the tester at the pump outlet and measure case drain flow with a separate flow meter in the drain line. Hydraulic power is flow multiplied by pressure: HP = GPM × PSI ÷ 1714, or kW = LPM × bar ÷ 600. Falling output flow together with rising case drain flow means internal wear. In hydrostatic transmissions the pump case drain, motor case drain and charge pump are connected in series, so charge pump flow must be allowed for. Any real increase in case flow indicates a pump or motor problem.
Three tests are used:
- No-load test: run the motor with no load and a tachometer on the shaft. Flow and RPM should match the manufacturer's specification. A drop in RPM means lost efficiency.
- Loaded test: repeat while loading the motor and compare with the specification and the unloaded result.
- Simulated load test: reverse the pump flow, use the tester's loading valve to create back pressure, and measure case drain flow. Falling RPM with rising case flow under load shows motor wear.
Check the manufacturer's maximum back pressure first. A motor with no external drain cannot carry a back pressure load.
Install the tester between the pump discharge port and the motor inlet. Run the pump test to check volumetric efficiency, then run the motor tests with a tachometer. Add a variable area flow meter on the case drain to read pump and motor case flow while you load the system. Bi-directional flow measurement helps because a hydrostatic circuit can flow either way.
Put a control valve into a power output mode with the output flow blocked, for example a cylinder at the end of its stroke. Close the tester's loading valve slowly while watching pressure. Pressure rises until the relief valve opens, so record that pressure and repeat to check the setting. For a relief valve in a separate housing, use the tee configuration on the line between the pump and the valve. Increase pressure slowly: with the relief valve isolated, pressures above its setting can cause injury or damage. Relief valves often start to open before full pressure, so a large drop in flow compared with the pump test indicates a faulty valve.
Isolate the motor or cylinder and connect the tester output to the valve's B port. Slowly close the loading valve to rated pump pressure and repeat for every operating position of every valve. If components are healthy, pressure and flow match the pump test. A flow drop in any position indicates leakage. A drop that is the same in all positions points to the relief valve, so check the relief valve first. If flow recovers when the cylinder or motor is disconnected, the actuator is faulty.
Install the tester on the rod or cap side. With the loading valve open, extension and retraction times can be set, verified and logged. Cylinder speed is inches per minute = (231 × GPM) ÷ area in sq in, and force is pressure × area, checked at the end of the stroke. A drop in pressure at full stroke could indicate worn piston seals. If flow or pressure falls in a valve position, suspect valve leakage.
Internal leakage turns hydraulic energy into heat. Check the oil level, pump speed, lines and external leaks first. Then test in this order: pump flow, relief valve, directional control valves, then the motor or cylinder. The component where flow or pressure falls under test is the one to repair. Using the tester flow-and-pressure data avoids replacing good parts.
Yes, with the Flo-Check USB analyzer. It samples at 10 kHz and records every second the average flow and temperature plus minimum, maximum and average pressure. This captures the amplitude and timing of spikes up to 10,000 psi with 0.2 millisecond response, which is useful for intermittent faults. High and low alarms can be set for flow, pressure and temperature, and alarm events are written to the log file.
Test benches & data logging
Yes. The Flo-Check USB can be added to any existing test stand for diagnostics, calibration, certification and data logging of hydraulic components. It records bi-directional flow, which suits motors and cylinders. Fit it on the supply side of the bench so that any contamination passed by the unit under test does not reach it. Recorded data can be stored for future reference, or printed and sent with the repaired unit as proof of performance.
- Flo-Check USB: PC logging, alarms and power calculation, with a loading valve for load tests. Suited to bench testing and service reports.
- F6100 sensor arrays with load valve: flow output as frequency, 4-20 mA or 0-5 VDC, with optional pressure and temperature sensors, for connecting to PLCs, recorders and displays.
- Activa and Ultima sensor arrays: flow, pressure and temperature in one compact unit with only one line break, for test stands and permanent monitoring.
- Turbine flow sensors (Classic, Quad): flow-only sensors for fixed installations, with Quad giving bi-directional measurement.
The Flo-Check USB software records readings once per second to a comma-separated (.csv) file that opens in Excel or other spreadsheets. You can record all points continuously or capture points manually, and the file header includes the device ID, serial number, model and units. For example, a 2-minute recording gives 120 data rows. Settings such as units and alarm limits can be saved as a configuration file and reloaded for repeat tests, which suits routine bench work.
Sensor arrays and turbine flow sensors can output frequency, 4-20 mA or 0-5 VDC signals that connect to PCs, PLCs, recorders and Flo-tech digital displays. The Flo-Check USB connects to a Windows PC through USB and is powered by it (5 VDC, about 100 mA). The MC4000 handheld takes five sensor inputs (flow, two pressure, temperature and RPM) and has 2.5 MB of data logging.
Industry applications
Yes. Equipment on rigs, midstream sites and defence installations is costly to move, so a portable tester goes to the machine instead. The Flo-Check USB is rated to 6,000 psi (414 bar) with 10,000 psi transients, handles fluid up to 150 °C, and includes an internal burst disc rated at 7,500 psi differential. Hazardous-area, marine or military certification is not stated in the manuals, so confirm any requirement before specifying.
Pitch, yaw and brake hydraulics can be tested in place with a compact tester, avoiding a lift of heavy equipment. Measure pump flow and pressure, then check valve leakage and pressure hold. PFM testers are battery powered (four AA cells, about 50 hours) and weigh from 13.85 lb (6.3 kg), and the Flo-Check USB runs from a laptop USB port. Always follow the turbine manufacturer's isolation and safety procedures.
Yes. Cranes, winches, steering gear, hatch covers and hydraulic power units can be tested in place, saving dry-dock and workshop time. Check the fluid type and seal material first: Flo-Check USB seals are Viton as standard with EPR optional, and PFM seals are Buna N standard with Viton and EPR optional.
Record before-and-after flow, pressure, temperature and power readings with the fluid type and test conditions. The logged .csv file gives a traceable record for customers, audits and warranty claims, and can be sent with a repaired pump or motor.
Choosing a model & specifications
Flo-tech Instrument Summary
| Instrument | What It's For |
|---|---|
| MC4000 Handheld Analyzer | Portable hydraulic analyzer with 2 pressure, 1 flow, and 1 RPM input, featuring 2.5 MB on-board data logging for field testing and diagnostics. |
| PFM6 / PFM6BD Portable Tester | Portable flow meter that simultaneously measures flow, pressure, and temperature up to 6,000 PSI. The PFM6BD model supports bi-directional flow measurement. |
| F6100 Sensor Array | Turbine sensor array with an integral load valve, designed for hydraulic test rigs and system performance testing. |
| Classic / Quad Turbine Sensors | High-accuracy in-line turbine flow sensors for permanent installation in hydraulic test stands and monitoring systems. |
| F6600 / F6700 Digital Displays | Panel-mounted digital displays that provide real-time readouts of data from turbine flow sensors for continuous monitoring. |
Flow ranges for each model are in the catalog and manuals. Send us your pump size and system pressure and we will match the model.
- Flow accuracy: ±1% of reading at 32 cSt, repeatability ±0.2%
- Pressure accuracy: ±0.5% BFSL, response 0.2 ms
- Pressure rating: up to 6,000 psi (414 bar), with 10,000 psi transients
- Fluid temperature: -40 to 150 °C; ambient 0 to 85 °C
- Model ranges: F7164/F7165 (SAE 12 or G 3/4) 2 to 30 gpm; F7160/F7162 (SAE 16 or G 1) 3 to 85 gpm; F7161/F7163 (SAE 24 or G 1-1/2) 7 to 199.9 gpm
- Units: psi, bar, kPa, MPa, kg/cm²; gpm or lpm; °F or °C; HP or kW
- Weight: 17 lb (7.71 kg) or 20 lb (9.07 kg) depending on model
PFM testers offer flow accuracy of ±1% of full scale, repeatability of ±0.2%, pressure up to 6,000 psi (414 bar) and fluid temperature -20 to 150 °C. The PFM6BD reverse-flow accuracy is ±2% of full scale. The PFM8 adds digital pressure and a power (HP and kW) display, and switches between US and metric in the field. PFM6 and PFM6BD are available in CE versions. The PFM8 pressure display needs at least 200 psi to activate and the unit switches itself off after five minutes without flow.
Calibration is done with 32 cSt (150 SUS) hydraulic oil. The stated ±1% accuracy applies across a viscosity range of about 25 to 500 SUS (2 to 110 cSt). For fire-resistant, synthetic or other fluids, tell us the fluid and viscosity so we can confirm compatibility.
The loading valve creates a controlled restriction to raise pressure. All testers ship with it closed, so open it fully (counterclockwise) before starting the pump, or injury and equipment damage can result. The reverse-flow testers are not designed for high pressure with the valve fully closed in the reverse direction, where maximum pressure is limited to 2,000 psi (138 bar). Internal burst discs (F1614-7500, 7,500 psi) protect the instrument. Do not stand in front of the burst disc vent, and use hoses and fittings rated above system pressure.