Small Hydraulic Power Packs from Concord Hydraulics
Since 1982, Concord Hydraulics has been one of India’s most trusted designers and manufacturers of custom hydraulic power packs. Our small HPU range bridges the gap between portable mini units and large industrial systems — delivering the continuous-duty performance demanded by construction machinery, mobile service equipment, dock levellers, and truck-mounted systems, in a compact and cost-effective package.
Where a mini power pack handles intermittent, low-flow tasks, a small HPU is built for small-scale continuous operation — running steadily, managing higher flow demands, and withstanding the rigours of field deployment. Concord engineers every small power pack to the client’s exact application, space constraints, and regulatory requirements.
3 – 15 kW
Electric Motor Range
8 – 50 L/min
Flow Rate
Up to 300 bar
Maximum Pressure
15 – 100 L
Reservoir Capacity
What Is a Small Hydraulic Power Pack?
A small hydraulic power pack is a self-contained hydraulic unit with an electric motor (3–15 kW) or small petrol/diesel engine (5–20 HP), a hydraulic pump, a medium-volume reservoir (15–100 L), pressure and directional control valves, filtration, and cooling — all integrated on a single baseframe or skid.
Unlike mini HPUs designed for intermittent portable tasks, small power packs are rated for continuous-duty operation. They deliver sustained flows of 8–50 L/min at pressures to 300 bar, making them the standard choice for mobile construction equipment, dock and warehouse systems, and truck-mounted hydraulic tools where the unit runs for extended periods without cycling off.
Key Characteristics
- Continuous-duty rated — designed for sustained operation, not just intermittent cycles
- Higher flow capacity (8–50 L/min) suitable for multi-actuator circuits
- Medium reservoir volume (15–100 L) for thermal management during extended runs
- Electric motor (single or three-phase) or petrol/diesel engine drive
- Integrated cooling (air-blast or water-cooled heat exchanger) on continuous-duty builds
- Skid, frame, or trailer-mounted for mobile and fixed-installation use
- Compatible with directional, pressure, and flow control valve manifolds
Technical Specifications
Standard Specification Envelope: All Concord small HPUs are engineered to order. The table below defines the standard specification envelope; custom configurations including special voltages, certifications, and circuit layouts are available on request.
| Parameter | Specification |
|---|---|
| Drive — Electric | Three-phase motor, 3 kW to 15 kW (4–20 HP); single-phase on request up to 5.5 kW |
| Drive — Engine | Petrol engine 5–15 HP; diesel engine 5–20 HP for outdoor and remote deployments |
| Flow Rate | 8 L/min to 50 L/min; adjustable via pump selection, speed, or variable-speed drive |
| Operating Pressure | Up to 300 bar (~4,350 psi); relief valve factory-set; dual-pressure circuits available |
| Reservoir Capacity | 15 litres to 100 litres; mild steel, stainless steel, or aluminium alloy |
| Pump Types | Gear pump (standard); vane pump; piston pump for high-pressure or variable-flow duty |
| Motor Voltages (AC) | Three-phase 380 V, 400 V, 415 V, 480 V; single-phase 220–240 V on request |
| DC / Generator Options | Available for engine-driven and battery/generator-powered mobile configurations |
| Cooling | Air-blast heat exchanger (standard on continuous duty); water-cooled on request |
| Tank Material | MS with heat-resistant epoxy paint; 304/316 SS and aluminium alloy on request |
| Manifold / Valve Block | Carbon steel; SG iron; stainless steel for corrosive or food-grade environments |
| Filtration | Return-line filter with bypass indicator; suction strainer; high-pressure inline filter on request |
| Fluid Compatibility | Mineral hydraulic oil (ISO VG 32–68); fire-resistant fluid (HFA/HFB/HFD) on request |
| Circuit Options | Single or double-acting; load-sensing; unloading valve; accumulator charging circuit |
| Mounting | Skid / baseframe (standard); trailer-mounted; panel or bracket mount on request |
| Protection | IP54 standard; IP65 on request; ATEX / IECEx Zone 1 and Zone 2 available |
| Finish | Epoxy primer + polyurethane topcoat; anti-corrosion treatment; SS enclosure on request |
| Cleanliness (option) | NAS 1638 Class 6–7 / ISO 4406 cleanliness certification available on request |
| Noise (guidance) | Typically 65–75 dB(A) at 1 m; acoustic enclosure option for noise-sensitive installations |
Electric-Driven vs. Engine-Driven Small HPUs
The choice between electric and engine drive for a small power pack depends on power availability, duty cycle, location, and emissions requirements. Concord supplies both configurations, often to the same flow and pressure specification.
| Aspect | Electric-Driven HPU | Engine-Driven HPU |
|---|---|---|
| Best For | Fixed sites, workshops, warehouses, construction sites with mains supply | Remote sites, outdoor operations, locations without reliable grid power |
| Power Source | Mains 3-phase AC (standard); single-phase or DC on request | Petrol (5–15 HP) or diesel (5–20 HP) engine |
| Duty Cycle | Continuous operation; motor duty class S1 or S3 | Continuous within engine rating; regular service required |
| Noise Level | Low to moderate; suitable for enclosed workshops | Higher; open-air or ventilated enclosures required |
| Emissions | Zero at point of use; suitable for indoor installation | Exhaust emissions; outdoor or well-ventilated areas only |
| Mobility | Constrained by power cable; skid or fixed installation | Self-contained; trailer or skid-mounted for full mobility |
| Maintenance | Minimal; electric motor near-maintenance-free | Engine oil, filter, and service intervals required |
| Start Method | DOL, star-delta, or soft-starter to manage inrush current | Recoil, electric, or remote start; key-switch options |
| Typical Use | Dock levellers, small presses, warehouse equipment, mobile rigs on-site | Skid-mounted service rigs, truck-mounted tools, field use |
Applications for Small Hydraulic Power Packs
Small HPUs serve a broad range of industries where continuous, sustained hydraulic power is required but large-scale industrial plant infrastructure is either unavailable or unnecessary. The following are principal application areas served by Concord’s small power pack range.
Small Construction Machines
Compact excavators, mini loaders, trench compactors, vibro-rollers, and attachments for skid-steer and telescopic handlers requiring a dedicated self-contained HPU.
Mobile Service Rigs
Truck-mounted hydraulic service units for field maintenance, pipeline inspection, and equipment repair — engine-driven for complete grid independence.
Dock Levellers
Electric small HPUs powering hydraulic dock levelling platforms and pit levellers at warehouses, logistics centres, and loading bays for continuous shift operation.
Truck-Mounted Equipment
Crane trucks (HIAB-type), tipper bodies, hook-loaders, refrigerated unit hydraulics, and timber grabs powered by PTO-driven or stand-alone engine HPUs.
Agricultural Machinery
Tractor-independent HPUs for seed drills, sprayer booms, vegetable harvesters, and irrigation pivots requiring consistent hydraulic power away from the tractor circuit.
Industrial Presses
Small hydraulic presses for forming, punching, clinching, and bonding in light manufacturing and workshop environments requiring compact continuous-duty HPUs.
Marine Deck Equipment
Winches, anchor windlasses, hatch actuators, and stabiliser fin systems on coastal craft, fishing vessels, and small offshore support boats.
Car Park & Access Systems
Hydraulic barriers, rising bollards, car park ramps, and automated gate systems requiring reliable electric HPUs for frequent, continuous cycle operation.
Waste Management Equipment
Refuse compactors, skip loaders, and baling presses requiring continuous electric HPUs on fixed installations or engine drive on mobile units.
Timber & Forest Machinery
Log splitters, firewood processors, wood chippers, and timber loading cranes — engine-driven for field independence.
HVAC & Building Services
Hydraulic actuators for large dampers, industrial valves, and building services equipment requiring compact electric HPUs integrated into plant rooms.
Testing & Calibration Rigs
Component proof-test benches, valve calibration rigs, and endurance-test fixtures in quality control and R&D environments.
Design & Configuration Options
Concord Hydraulics designs every small HPU in SolidWorks and Solid Edge 3D CAD. Each unit is engineered from first principles to the client’s spatial envelope, duty cycle, and circuit requirements. Key configuration choices include:
Tank Orientation
- Vertical (DIN-type): motor and pump mounted vertically on the tank — compact footprint, preferred for European-standard automation
- Horizontal (JIC/NFPA-type): motor and pump horizontal on top of tank — NFPA/JIC standard, preferred for US-standard and large flexible piping arrangements
- L-type (Vickers-style): modular split layout for custom installations requiring separate pump and motor positions
- Overhead tank: tank elevated above pump for gravity-flooded inlet — improves cavitation resistance for high-speed pumps
Motor Starting Methods
- Direct On Line (DOL): simplest, lowest cost; suitable for smaller motors on stiff supplies
- Star-Delta: reduced inrush; standard for 5.5 kW and above on most site supplies
- Soft-Starter: smooth ramp-up; recommended for frequent starting and noise-sensitive installations
- Variable Speed Drive (VSD/inverter): maximum energy saving and precise flow control
Control Options
- Single-acting or double-acting directional control
- Unloading valve: pump unloads at low pressure when actuators are at rest — reduces heat generation and energy use
- Accumulator charging circuit: stores energy and reduces motor on-time for intermittent high-demand cycles
- Load-sensing circuit: pump output matches demand, minimising energy waste
- Proportional valve control: variable speed/force via electronic controller or PLC interface
Cooling Options
- Air-blast heat exchanger (fan-cooled): standard for continuous-duty electric builds
- Water-to-oil heat exchanger: preferred where cooling water is available (factory mains, cooling towers)
- No cooler (short-duty/intermittent): where duty cycle keeps fluid temperature within limits
Materials of Construction
| Component | Material Options |
|---|---|
| Frame / Skid | Mild steel (MS) fabricated and painted; hot-dip galvanised for outdoor/marine duty |
| Tank / Reservoir | MS with heat-resistant epoxy paint (standard); 304/316 stainless steel; aluminium alloy |
| Manifold Blocks | Carbon steel; spheroidal graphite (SG) iron; 316 stainless steel for aggressive media |
| Pump Body | Cast iron (standard); aluminium; stainless steel for corrosive duty |
| Valve Block | Aluminium alloy (standard); carbon steel; stainless steel on request |
| Heat Exchanger | Aluminium core (air-blast); copper/brass or stainless steel (water-to-oil) |
| Hose / Tubing | SAE J517 hydraulic hose (standard); SS tube for high-pressure or chemically aggressive circuits |
| Seals | NBR (standard); Viton / FKM for elevated temperature or chemical exposure |
| Surface Treatment | Epoxy primer + polyurethane topcoat; hot-dip galvanising; electroless nickel plating on request |
How Does a Small HPU Compare to Mini and Medium Units?
Understanding where the small HPU sits in the Concord product range helps in selecting the right unit for your application:
| Parameter | Mini HPU | Small HPU | Medium HPU |
|---|---|---|---|
| Drive Power | 0.25 – 3 kW / <5 HP | 3 – 15 kW / 5–20 HP | 15 – 75 kW / 20–100 HP |
| Flow Rate | 0.1 – 8 L/min | 8 – 50 L/min | 50 – 250 L/min |
| Max Pressure | Up to 250 bar | Up to 300 bar | Up to 350 bar |
| Reservoir | 1 – 15 L | 15 – 100 L | 100 – 600 L |
| Duty Cycle | Intermittent | Continuous | Continuous heavy-duty |
Why Choose Concord Hydraulics for Small HPUs?
40+ Years of Engineering Heritage
Founded in 1982 by Vickers-trained engineers. The same precision used for ISRO launch vehicle hydraulics and Indian Army missile systems is applied to every small HPU we build.
Fully Custom-Engineered
Every small HPU is 3D-modelled in SolidWorks to your exact space, pressure, flow, duty cycle, and regulatory requirements. No catalogue compromises.
In-House Testing & Validation
All units are pressure-tested and function-verified before dispatch. NAS/ISO cleanliness certification available. Our Hardline Fatigue Lab is rated to 420 bar and 5,000 LPM flushing.
ISO 9001:2015 Certified
Palghar manufacturing holds ISO 9001:2015, NSCI, and SSI certifications. Authorised Sun Hydraulics (USA) partner for cartridge valves and system components.
World-Class Components
Premium pump brands, international-standard directional and pressure valves, advanced filtration, and anti-corrosion finishes for reliable operation under all climatic conditions.
End-to-End Support
Design, manufacture, piping, commissioning, and after-sales service under one roof. Hydraulic engineering training available at our Mumbai facility for your team.
Frequently Asked Questions
Mini HPUs (0.25–3 kW, 0.1–8 L/min) are designed for portable, intermittent-duty tasks such as tail lifts, wheelchair lifts, and portable tools. Small HPUs (3–15 kW, 8–50 L/min) are built for sustained continuous operation — they run longer, move more fluid, and handle higher thermal loads. The key difference is duty cycle and flow capacity.
Yes. Electric small HPUs in the 4–7.5 kW range are the standard choice for hydraulic dock levellers, typically running at 15–30 L/min at pressures of 150–200 bar. Concord will size the motor, pump, and heat exchanger to your leveller’s actuation cycle and shift pattern to ensure reliable continuous operation.
For motors up to 5.5 kW on most industrial supplies, Direct On Line (DOL) starting is standard. For 7.5 kW and above, star-delta or soft-starter is recommended to limit inrush current and protect the supply. If the unit starts frequently or operates near the limit of the supply breaker rating, a soft-starter or VSD is preferred. Concord will advise based on your site supply details.
For continuous-duty electric builds (more than 20–30 minutes of uninterrupted operation per session), an air-blast heat exchanger is standard practice. The reservoir volume (15–100 L) provides some thermal buffer, but without cooling, oil temperatures can exceed safe limits during extended runs. Concord will calculate the thermal balance for your duty cycle and specify cooling accordingly.
Yes. For outdoor installation, Concord specifies a hot-dip galvanised or stainless steel frame, IP65 protection for electrical components, a weather-protective acoustic enclosure on request, and corrosion-resistant paint systems. Engine-driven variants are inherently suited to outdoor deployment.
Standard small HPUs: 4–8 weeks from order confirmation. Custom builds requiring special materials, ATEX certification, acoustic enclosures, or complex valve manifolds: 8–14 weeks. Please contact our engineering team with your specification for a confirmed project schedule and quotation.
Yes. Concord provides complete end-to-end support: system design, manufacturing, hydraulic piping, pressure testing, NAS/ISO cleanliness flushing, on-site commissioning, and ongoing technical support. Hydraulic engineering training for your operators and maintenance team is also available at our Mumbai facility.